Ushbu issiqlikni qayta tiklash tizimi suv tizimining issiqlik pompasiga ulanishi mumkin.Kollektor trubkasidagi suv ERV ni ulaydi, eshikning kirish havosini oldindan qizdiradi, xonaga kiradigan toza havo haroratini yaxshilaydi va ichki muhitning qulayligini yaxshilaydi.
Havo oqimi: 250~500m³/soat
Model: TFWC A1 seriyali
1, Toza havoni tozalash + Energiyani tiklash + Isitish va sovutish
2、Havo oqimi: 250-500 m³/soat
3, Entalpiya almashinuvi yadrosi
4、Filtr: G4 asosiy ekrani +Hepa12 ekrani
5, Yon eshikni ta'mirlash
6, PTC isitish
7, Bypass funktsiyasi
Xususiy turar joy
Markaziy isitish punkti
Tijorat
Mehmonxona
Model | Nominal havo oqimi (m³/soat) | Nominal ESP(Pa) | Temp.Eff. (%) | Shovqin (dB(A)) | Tozalash samaradorligi | Volt.(V/Gts) | Kirish quvvati (Vt) | Isitish/sovutish kaloriyasi (Vt)
| NW(kg) | Hajmi (mm) | Nazorat shakli | Ulanish hajmi |
TFWC-025 (A1-1D2) | 250 | 100(200) | 75-80 | 35 | 99% | 210-240/50 | 100(300*2) | 500 ~ 1500 | 58 | 1200*780*260 | Intellektual boshqaruv/APP | ph150 |
TFWC-035 (A1-1D2) | 350 | 100(200) | 75-80 | 37 | 210-240/50 | 130(300*2) | 500 ~ 1500 | 58 | 1200*780*260 | ph150 | ||
TFWC-500 (A1-1D2) | 500 | 100 | 75-80 | 40 | 210-240/50 | 220(300*2) | 500 ~ 1500 | 58 | 1200*780*260 | ph200 |
G4+H12 filtri)*2 Yana toza havo
Qarama-qarshi oqim o'zaro entalpiya almashinuvi yadrosi, yuqori issiqlik almashinuvi samaradorligi
Suv batareyasi ERV o'rnatish sxemasi
1: Issiqlik pompasi konditsionerining tashqi bloki
2: polni isitish
3: Suv idishi
4: ERV boshqaruvchisi
5: ERV issiqlik pompasi
O'rnatish joyi faqat ma'lumot uchun.O'rnatishni dizayn sxemasiga muvofiq bajaring
Suv batareyasining ERV isitish effekti haqida nima deyish mumkin?
Keling, eksperimental ma'lumotlar to'plamini ko'rib chiqaylik
Oldindan isitish bobini yukini hisoblash (Xitoydagi standart Yinchuan atmosfera bosimi qiymatini so'rang: 88390pa) | |||||||
Shamol tezligi | Bobinning kirish harorati (℃) /nisbiy namlik (%) | Bobinning kirish entalpiyasi (KJ/KG) | Bobinning kirish harorati (℃) /nisbiy namlik (%) | Bobinning kirish entalpiyasi (KJ/KG) | Havo oqimi (m³/soat) | Havo zichligi (kg/m³) | Oldindan isitish yuki (V) |
Yuqori | 1.93/43.01 | 7.2 | 20.40/13.78 | 26.5 | 300 | 1.117 | 1797 yil |
O'rta | 1.93/43.01 | 7.2 | 21.77/13.34 | 28.3 | 250 | 1.117 | 1637 |
Past | 1.93/43.01 | 7.2 | 23.17/10.76 | 28.9 | 200 | 1.117 | 1347 |
1, sinov maydonchasi lasan suvining kirish harorati: 32,3 ℃, chiqish harorati: 22,1 ℃;
2. Bobinning kirish va chiqish havosining entalpiya farqiga ko'ra, lasanning issiqlik yuki hisoblanadi.
3. Standart Yinchuan atmosfera bosimi qiymatini so'rang: 88390pa
Shahar issiq suvining isishi 30 ℃ dan past bo'lmaganda, yuqori / o'rta / past tezlikda uch quvurli yangi fanning (oldindan isitish bobini bilan) oldindan isitish quvvati:
Yuqori tezlik 1797 Vt, o'rtacha tezlik 1637 Vt, past tezlik 1347 Vt
Toza havoni oldindan isitish talablariga javob bering.
DC vosita: Kuchli motorlar tomonidan yuqori energiya samaradorligi va ekologiya
Yuviladigan almashinuv yadrosi:Entalpiya almashinuvi yadrosini yuvishi mumkin bo'lgan va 3-10 yil uzoq umrga ega bo'lgan modifikatsiyalangan membrana
Energiyani qayta tiklash shamollatish texnologiyasi: issiqlikni qayta tiklash samaradorligi 70% dan oshishi mumkin
Aqlli boshqaruv: APP+Aqlli kontroller